The new light scattering (LS) detector (DAWN HELEOS II) and refractive index (RI) detectors (OptiLab rEX) have ~60 times bigger dynamic range, which allows determination of MWs of protein samples from ~ 1 ug/ml to a few mg/mL (concentration used during structural studies by NMR or X-ray).
I may also include fluorescence detection for analysis of eluting peaks- please indicate such need if your research may benefit from this feature.
We plan on installing an automated gradient set up (as described by Attri and Minton, (2005a, 2005b) to analyze protein association processes. Such gradient experiment (either with one protein or mixing two interacting partners) would allow determination of association constant.
The FFF technology is reviewed in:
Giddings,J.C. (1993) Science, 260, 1456-1466
"Field-flow
fractionation: Analysis of macromolecular, colloidal, and particulate materials"
Fraunhofer, W. , Winter, G. (2004) European Journal of Pharmaceutics
and Biopharmaceutics, 58, 369-383
"
The use of asymmetrical flow field-flow fractionation in pharmaceutics
and biopharmaceutics"
Reschiglian,Pierluigi; Zattoni,Andrea; Roda,Barbara; Michelini,Elisa;
Roda,Aldo (2005) Trends in Biotechnology, 23, 475-483
"Field-flow
fractionation and biotechnology"
Selected Applications:
Nanoparticles as drug carriers
Fraunhofer,W.; Winter,G.; Coester,C. (2004) Anal Chemistry, 76, 1909-1920
"Asymmetrical
Flow Field-Flow Fractionation and Multiangle Light Scattering for Analysis
of Gelatin Nanoparticle Drug Carrier Systems"
Prion proteins:
Silveira,Jay R.; Raymond,Gregory J.; Hughson,Andrew G.; Race,Richard
E.; Sim,Valerie L.; Hayes,Stanley F.; Caughey,Byron (2005) Nature
437, 257-261 (8 September 2005)
"The
most infectious prion protein particles"
Liposomes:
Shuliang Li and Andre F. Palmer (2004) Langmuir, 20, 4629-4639
"Effect
of Actin Concentration on the Structure of Actin-Containing Liposomes"
Korgel,Brian A.; van Zanten,John H.; Monbouquette,Harold G. (1998) Biophys.
J., 74, 3264-3272
"Vesicle
Size Distributions Measured by Flow Field-Flow Fractionation Coupled with
Multiangle Light Scattering"
Moon,M.H.; Park,I.; Kim,Y. (1998) J. Chromatography A, 813, 91-100
"Size
characterization of liposomes by flow field-flow fractionation and photon
correlation spectroscopy. Effect of ionic strength and pH of carrier solutions"
Ribosomes:
Andersson,C.I.; Arfvidsson,C.; Kallio,P.T.; Wahlund,K.G.; Bulow,L.
(2003) Biotechnol. Lett. 25, 1499-1504
"Enhanced
ribosome and tRNA contents in Escherichia coli expressing a truncated Vitreoscilla
hemoglobin mutant analyzed by flow field-flow fractionation"
Environmental samples:
Baalousha,M.; Kammer,F.V.D.; Motelica-Heino,M.; Le Coustumer,P. (2005)
Journal of Chromatography A, 1093, 156-166
"Natural
sample fractionation by FlFFF-MALLS-TEM: Sample stabilization, preparation,
pre-concentration and fractionation"
|
|
ITC |
Spectrofluorometer |
Polarization System |
Service |
SPR
BiaCore |
Front Page |
|
|
|
|
|
|
|
|
Last Modified April, 2009 by Ewa Folta-Stogniew